| Technology |
| Standards | IEEE 802.3af/at for Power-over-Ethernet IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) |
| Interface |
| RJ45 Ports | 10/100/1000BaseT(X) for PoE OUT and DATA IN |
| PoE Pinout | V+, V+, V-, V- for pin 4, 5, 7, 8 (Midspan, MDI Alternative B) |
| Power Requirements |
| Input Voltage | 24/48 VDC, single input |
| Operating Voltage | 22 to 57 VDC |
| Input Current | 1.42 A @ 24 VDC |
| Overload Current Protection | Present |
| Connection | 1 removable 3-contact terminal block |
| Reverse Polarity Protection | Present |
| Power Consumption | Max. 4.08 W full loading without PD's consumption |
| Power Budget | Max. 30 W for 1 PD's consumption |
| Physical Characteristics |
| Housing | Plastic |
| IP Rating | IP30 protection |
| Dimensions | 24.9 × 100 × 86.2 mm (0.98 x 3.93 x 3.39 in) |
| Weight | 115 g (0.26 lb) |
| Installation | DIN-rail mounting |
| Environmental Limits |
| Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) |
| Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| Standards and Certifications |
| Safety | UL 508, EN 60950-1 (LVD) |
| EMC | EN 55032/24 |
| EMI | CISPR 32, FCC Part 15B Class A |
| EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV |
| IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m |
| IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV |
| IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV |
| IEC 61000-4-6 CS: Signal: 10 V IEC 61000-4-8 |
| Shock | IEC 60068-2-27 |
| Freefall | IEC 60068-2-32 |
| Vibration | IEC 60068-2-6 |
| MTBF (mean time between failures) |
| Time | 2,525,278 hrs |
| Standard | Telcordia (Bellcore), GB |